logo
Casa > prodotti > Misuratore di flusso di marca >
8800D Vortex Flow Transmitter – Reliable Steam, Gas, and Liquid Flow Measurement

8800D Vortex Flow Transmitter – Reliable Steam, Gas, and Liquid Flow Measurement

8800D vortex flow transmitter

flow meter for steam gas liquid

vortex flow meter with warranty

Luogo di origine:

Singapore

Certificazione:

ISO9001

Numero di modello:

8800

Contattici
Chiedi un preventivo
Dettagli del prodotto
tempo del esponse:
67 (default) ms personalizzabile
Produzione:
4-20mA o Pulso
Velocità di flusso:
0-± 32 m/s
Pressione operativa:
< 50 bar
Parola chiave:
misuratore di portata idraulico
Tipo di liquido:
Liquido
Gamma di conducibilità:
> 5 μs/cm
Segnale di uscita:
4-20 mA
Evidenziare:

8800D vortex flow transmitter

,

flow meter for steam gas liquid

,

vortex flow meter with warranty

Termini di pagamento e spedizione
Quantità di ordine minimo
1 pz
Prezzo
Negoziabile
Tempi di consegna
7 giorni di lavoro
Termini di pagamento
T/T
Descrizione di prodotto

8800D Vortex Flow Transmitter – Reliable Steam, Gas, and Liquid Flow Measurement

Product Description:

The Rosemount 8800D Vortex Flow Transmitter is a highly reliable and maintenance-free solution for measuring the flow of steam, gas, and liquid in industrial applications. Designed with a robust, gasket-free, all-cast construction and no moving parts, it ensures long-term stability and reduces potential leak points. Its advanced vortex-shedding technology delivers accurate and repeatable flow measurement, even under demanding process conditions. With multiple configuration options—including flanged, wafer, and reducer styles—the 8800D offers installation flexibility and broad applicability across power, chemical, oil & gas, and general process industries.


8800D Vortex Flow Transmitter – Reliable Steam, Gas, and Liquid Flow Measurement 0

Parameter Rosemount 8800D (Emerson) Yokogawa DY Series Siemens SITRANS FX330 ABB VortexMaster FSV450
Measurement Principle Vortex shedding, no moving parts Vortex shedding with dual sensor Vortex shedding with integrated pressure/temperature compensation Vortex shedding with multivariable capability
Media Steam, gas, liquid Steam, gas, liquid Steam, gas, liquid Steam, gas, liquid
Accuracy ±0.65% of rate (liquid), ±1% (gas/steam) ±0.75% of the rate ±0.75% of the rate ±0.75% of the rate
Repeatability ±0.2% ±0.2% ±0.2% ±0.2%
Pressure Rating Up to ANSI Class 1500 Up to Class 900 Up to PN100 / ASME 600 Up to PN100 / ASME 600
Temperature Range -200 °C to +400 °C -200 °C to +450 °C -200 °C to +240 °C -200 °C to +400 °C
Design Gasket-free, all-cast body, no leak points Dual-sensor redundancy Compact, modular transmitter Multivariable with DP/Temp integration
Output Options 4–20 mA, HART, FOUNDATION Fieldbus, Modbus 4–20 mA, HART, Fieldbus 4–20 mA, HART, PROFIBUS PA 4–20 mA, HART, PROFIBUS PA, Modbus
Special Features Maintenance-free, no moving parts, optional dual/quad redundancy Dual-sensor for safety, SIL certified Integrated pressure & temperature compensation Multivariable mass flow, SIL certified
Typical Applications Steam energy balance, chemical, oil & gas, power plants Power, chemical, safety-critical steam HVAC, utilities, chemical Power, chemical, oil & gas

Got it — you’d like an English “Applications” section for the Rosemount 8800D Vortex Flow Transmitter. Here’s a professional version you can use in catalogs, datasheets, or presentations:


Applications

The Rosemount 8800D Vortex Flow Transmitter is engineered for a wide range of industrial flow measurement tasks, delivering accurate and repeatable results across diverse process conditions. Typical applications include:

  • Steam Measurement
  • Saturated and superheated steam flow in power generation and district heating
  • Energy balancing and efficiency monitoring in utility systems
  • Gas Measurement
  • Compressed air distribution networks
  • Natural gas and industrial gas supply lines
  • Flue gas and exhaust monitoring in process industries
  • Liquid Measurement
  • Cooling water and boiler feedwater systems
  • Chemical feed and process liquids in refineries and chemical plants
  • General-purpose liquid flow in industrial utilities
  • Multivariable Applications
  • Mass flow and energy measurement with integrated temperature and pressure compensation
  • Safety Instrumented Systems (SIS) with dual or quad sensor configurations

Frequently Asked Questions (FAQ)

Q1. What is the Rosemount 8800D Vortex Flow Transmitter used for?
The 8800D is designed to measure the flow of steam, gas, and liquid in industrial processes. It is widely applied in power generation, chemical plants, oil & gas, and general utilities.

Q2. How does the 8800D measure flow?
It uses the vortex shedding principle, where vortices are formed as fluid passes a bluff body. The frequency of these vortices is directly proportional to the flow velocity, allowing accurate flow measurement.

Q3. What makes the 8800D different from other vortex flowmeters?
The 8800D features a gasket‑free, all‑cast body with no moving parts, eliminating potential leak points and reducing maintenance. It also offers dual and quad sensor configurations for safety‑critical applications.

Q4. What types of fluids can it measure?
It can measure saturated and superheated steam, compressed air, natural gas, industrial gases, cooling water, boiler feedwater, and a wide range of process liquids.

Q5. What is the accuracy of the 8800D?
Typical accuracy is ±0.65% of rate for liquids and ±1.0% of rate for gas and steam, with repeatability of ±0.2%.

Q6. What communication protocols are supported?
The transmitter supports 4–20 mA with HART, FOUNDATION Fieldbus, and Modbus protocols, ensuring compatibility with most control systems.

Q7. What installation options are available?
The 8800D is available in flanged, wafer, reducer, dual‑sensor, quad‑sensor, and high‑pressure designs, providing flexibility for different piping systems and process conditions.

Q8. Is the 8800D suitable for safety instrumented systems (SIS)?
Yes. Dual and quad sensor configurations are SIL‑certified, making them suitable for SIS applications where redundancy and reliability are critical.

Q9. What is the temperature and pressure range?
It can handle temperatures from –200 °C up to +400 °C and pressures up to ANSI Class 1500, depending on the configuration.

Q10. What are the maintenance requirements?
With no moving parts and a gasket‑free design, the 8800D requires minimal maintenance, reducing lifecycle costs and downtime.

Inviaci direttamente la tua richiesta.

Norme sulla privacy Buona qualità della Cina 3051 Trasmettitore Fornitore. © di Copyright 2025 Shaanxi Huibo Electromechanical Technology Co., Ltd . Tutti i diritti riservati.